Pyro MI Enhanced Grade Wiring Cable System - Light Duty

These cables are rated at 500V and are suitable for use where the voltage between the conductor and sheath and between conductors does not exceed 500V rms AC or 500V DC.

Pyrotenax Part CodeDescriptionOuter Sheath
CC2L12 Core 1mm² Pyro MI Light Duty CableBare Cable
CCM2L12 Core 1mm² Pyro MI Light Duty CableLSF Covered
CC2L1.52 Core 1.5mm² Pyro MI Light Duty CableBare Cable
CCM2L1.52 Core 1.5mm² Pyro MI Light Duty CableLSF Covered
CC2L2.52 Core 2.5mm² Pyro MI Light Duty CableBare Cable
CCM2L2.52 Core 2.5mm² Pyro MI Light Duty CableLSF Covered
CC2L42 Core 4mm² Pyro MI Light Duty CableBare Cable
CCM2L42 Core 4mm² Pyro MI Light Duty CableLSF Covered
CCM3L13 Core 1mm² Pyro MI Light Duty CableLSF Covered
CC3L1.53 Core 1.5mm² Pyro MI Light Duty CableBare Cable
CCM3L1.53 Core 1.5mm² Pyro MI Light Duty CableLSF Covered
CC3L2.53 Core 2.5mm² Pyro MI Light Duty CableBare Cable
CCM3L2.53 Core 2.5mm² Pyro MI Light Duty CableLSF Covered
CCM4L14 Core 1mm² Pyro MI Light Duty CableLSF Covered
CC4L1.54 Core 1.5mm² Pyro MI Light Duty CableBare Cable
CCM4L1.54 Core 1.5mm² Pyro MI Light Duty CableLSF Covered
CC4L2.54 Core 2.5mm² Pyro MI Light Duty CableBare Cable
CCM4L2.54 Core 2.5mm² Pyro MI Light Duty CableLSF Covered
CCM7L17 Core 1mm² Pyro MI Light Duty CableLSF Covered
CC7L1.57 Core 1.5mm² Pyro MI Light Duty CableBare Cable
CCM7L1.57 Core 1.5mm² Pyro MI Light Duty CableLSF Covered
CC7L2.57 Core 2.5mm² Pyro MI Light Duty CableBare Cable
CCM7L2.57 Core 2.5mm² Pyro MI Light Duty CableLSF Covered

Standards and Approvals

Cables

Pyro Mi Wiring Cables are manufactured, tested and LPCB approved to:

  • BS EN 60702-1.
  • LPCB approved to BS 8434-2, BS 5839-1 Clause 26.2 (Enhanced) and BS EN 50200 Class PH 120.
  • BS 8434—Methods of test for assessment of the fire integrity of electric cables Part 1: Test for unprotected small cables for use in emergency circuits
  • BS EN 50200 with the addition of water spray. Part 2—Test for unprotected small cables for use in emergency circuits
  • BS EN 50200 with a 930°C flame and with water spray.
  • BS 6387-1994 Performance Requirements for Cables Required to Maintain Circuit Integrity under Fire Conditions Categories C, W and Z.
  • IEC 60331—Tests for Electric Cables under fire conditions.
  • Underwriters Laboratories—UL2196-USA, ULC-S139-Canada. Tests for fire resistant cables.
  • London Underground Fire Survival Cable (MICC) EME-SP-14-028-A1.

Pyro Mi Terminations

Pyro Mi Terminations are tested in accordance with:

  • BS EN 60702: Part 2. Pyro Mi Terminations are Certified for use in potentially explosive atmospheres.
  • Glands—BASEEFA 03ATEX0347X.
  • Increased Safety Seals—BASEEFA 02ATEX0194U.