MICC Wiring Cable—Light Duty
These cables are rated at 500V and are suitable for use where the voltage between the conductor and sheath and between conductors does not exceed 500V rms AC or 500V DC.
MICC cable is also available with an optional LSZH sheath. A choice of the following colours is generally available: red, orange, black or white.
| Part Code | Alt. Code | Description | Outer Sheath |
|---|---|---|---|
| 2L1.5 | CC2L1.5 | 2 Core 1.5mm² MICC Light Duty Cable | Bare Cable |
| 2L2.5 | CC2L2.5 | 2 Core 2.5mm² MICC Light Duty Cable | Bare Cable |
| 2L4 | CC2L4 | 2 Core 4mm² MICC Light Duty Cable | Bare Cable |
| 3L1.5 | CC3L1.5 | 3 Core 1.5mm² MICC Light Duty Cable | Bare Cable |
| 3L2.5 | CC3L2.5 | 3 Core 2.5mm² MICC Light Duty Cable | Bare Cable |
| 4L1.5 | CC4L1.5 | 4 Core 1.5mm² MICC Light Duty Cable | Bare Cable |
| 4L2.5 | CC4L2.5 | 4 Core 2.5mm² MICC Light Duty Cable | Bare Cable |
| 7L1.5 | CC7L1.5 | 7 Core 1.5mm² MICC Light Duty Cable | Bare Cable |
| 7L2.5 | CC7L2.5 | 7 Core 2.5mm² MICC Light Duty Cable | Bare Cable |
| Part Code | Alt. Code | Description | Outer Sheath |
|---|---|---|---|
| 2L1.5-LSF | CCM2L1.5 | 2 Core 1.5mm² MICC Light Duty Cable | LSF Covered |
| 2L2.5-LSF | CCM2L2.5 | 2 Core 2.5mm² MICC Light Duty Cable | LSF Covered |
| 2L4-LSF | CCM2L4 | 2 Core 4mm² MICC Light Duty Cable | LSF Covered |
| 3L1.5-LSF | CCM3L1.5 | 3 Core 1.5mm² MICC Light Duty Cable | LSF Covered |
| 3L2.5-LSF | CCM3L2.5 | 3 Core 2.5mm² MICC Light Duty Cable | LSF Covered |
| 4L1.5-LSF | CCM4L1.5 | 4 Core 1.5mm² MICC Light Duty Cable | LSF Covered |
| 4L2.5-LSF | CCM4L2.5 | 4 Core 2.5mm² MICC Light Duty Cable | LSF Covered |
| 7L1.5-LSF | CCM7L1.5 | 7 Core 1.5mm² MICC Light Duty Cable | LSF Covered |
| 7L2.5-LSF | CCM7L2.5 | 7 Core 2.5mm² MICC Light Duty Cable | LSF Covered |
Standards and Approvals
Cables
MICC Wiring Cables are manufactured, tested and LPCB approved to:
- BS EN 60702-1.
- LPCB approved to BS 8434-2, BS 5839-1 Clause 26.2 (Enhanced) and BS EN 50200 Class PH 120.
- BS 8434—Methods of test for assessment of the fire integrity of electric cables Part 1: Test for unprotected small cables for use in emergency circuits
- BS EN 50200 with the addition of water spray. Part 2—Test for unprotected small cables for use in emergency circuits
- BS EN 50200 with a 930°C flame and with water spray.
- BS 6387-1994 Performance Requirements for Cables Required to Maintain Circuit Integrity under Fire Conditions Categories C, W and Z.
- IEC 60331—Tests for Electric Cables under fire conditions.
- Underwriters Laboratories—UL2196-USA, ULC-S139-Canada. Tests for fire resistant cables.
- London Underground Fire Survival Cable (MICC) EME-SP-14-028-A1.